Software in Medical Devices

To content | To menu | To search

Friday 31 May 2013

Got SOUP? - Part 3 - Runtimes, Frameworks

We saw in the first article of this series, what is a SOUP and what is not a SOUP, according to IEC 62304.
Then we continued in the second article by having a look at OS's and drivers.
Let's now see how to deal with runtimes.

Continue reading...

Friday 24 May 2013

Got SOUP? - Part 2 - OS, Drivers, Runtimes

We've seen in last article, what is a SOUP and what is not a SOUP, according to IEC 62304.
We've also seen that a lot of 3rd party software are SOUPs, to begin with OS, drivers, runtimes, Just-In-Time (JIT) compilers and frameworks.
How to deal with those to be compliant with IEC 62304?

Continue reading...

Friday 17 May 2013

Got SOUP? - Part 1 - Because every good software starts with SOUP

No need to reinvent the wheel when developing software. Everybody uses software made by 3rd parties, to begin with the operating system and general purpose libraries.
IEC 62304 has specific requirements about 3rd party software. What are these requirements and how do they affect software development and maintenance?

Continue reading...

Friday 10 May 2013

When computers prescribe better than doctors

Two computer science researchers of Indiana University have found that predictive algorithms can make better decisions that doctors, reported Indiana University News website.

Continue reading...

Friday 3 May 2013

Interoperability matters, Wireless devices ditto

Today, two publications of the AAMI about interoperability and wireless devices.

The first one is the report of the medical device interoperability summit. The summit was organized in october 2012 by the AAMI and the FDA.
The second one is the report of a workshop about wireless devices in healthcare. It was organized by the AAMI just after the interoperability summit.

Friday 26 April 2013

Latest news about IEC 62304 2nd Edition

Want to see latest news about IEC 62304 2nd Edition?
Have a look at this thread on Elsmar Cove Forum: Update on IEC 62304 revision.
This thread contains an interesting discussion about the topics that are being amended in IEC 62304 by IEC working group:

  • Safety classes,
  • SOUP,
  • Legacy software.

Enjoy.

Note: for those who don't know Elsmar Cove forum, it's probably the best forum about quality management and standards.

Friday 19 April 2013

FAQ related to the Implementation of EN 62304 published by TEAM-NB

The FAQ related to the Implementation of EN 62304 with respect to MDD 93/42/EEC was released by Team NB, the association of Notified Bodies.
You'll find in this FAQ many hot subjects I already mentioned in this blog:

  • When software is medical device,
  • What is software validation,
  • SOUP and legacy software,
  • Software risk assessment.

This FAQ shows that the state-of-the-art is still evolving. But I think that it has reached a point of consistency and stability. Many questions in the FAQ hadn't clear answers one or two years back.

Keep going!

Friday 12 April 2013

MD and IVD standards: IEC 60601-1 and IEC 61010-1, versus IEC 62304 - Part 2

In the previous post, we've seen when it's mandatory to be compliant both with IEC 60601-1 and IEC 62304, and when IEC 60601-1 alone is enough.

But some manufacturers don't apply IEC 60601-1, mainly because their devices are not in contact with the patient or cannot be qualified are medical devices. We find in these categories in-vitro diagnosis instruments and laboratory instruments.
These instruments usually fall in the scope of IEC 61010-1. Let's see now the relationship between IEC 61010-1 and IEC 62304.

Continue reading...

Friday 5 April 2013

MD and IVD standards: IEC 60601-1 and IEC 61010-1, versus IEC 62304 - Part 1

Manufacturers of medical devices often ask themselves the obvious question:
Is it mandatory to be compliant both with IEC 60601-1 and IEC 62304?

Similarly, manufacturers of in vitro diagnosis devices ask themselves:
Are my devices in the scope of IEC 62304?

Obviously, medical devices (MD) with electric or electronic components are in the scope of IEC 60601-1. And in-vitro diagnosis devices (IVD) with electric or electronic components are in the scope of IEC 61010-1.

Do MD and IVD that embed software, fall in the scope of IEC 62304?
This is not so obvious.

Continue reading...

Friday 29 March 2013

Brain Computer Interface - the future of healthcare

Brain Computer Interface is the term used for a very advanced kind of man machine interface. They allow to send orders to a machine through thought. Sensors are directly connected to the brain of the user and a computer interpret the neural signals to transform them in orders.

Continue reading...

Friday 22 March 2013

EU Guidances - What's new?

A few words about guidances in Europe. News are rare enough to point them out.
First, the guidance on electronic labelling came into force on 1st march 2013, see the MHRA website for some explanations and the original decision on the EU website.

Continue reading...

Friday 15 March 2013

Yet another man machine interface

Until the early 2000's, the mouse used to rule as absolute king over other man machine interfaces.
Since then, touchpads, touchscreens, touchless peripherals like the kinect and other devices have appeared and conquered large territories of mouse kingdom.

Continue reading...

Friday 8 March 2013

How to bring legacy software into line with IEC 62304? - part 3

We've seen in the two previous posts several solutions on how to treat legacy software according to IEC 62304.
But there is nothing equivalent to this discussion in IEC 62304. The standard is silent about these situations.

Continue reading...

Friday 1 March 2013

How to bring legacy software into line with IEC 62304? - part 2

We've seen in the last post how to manage changes in legacy software. Let's see it from another point of view: the type of legacy software.

Continue reading...

Friday 22 February 2013

How to bring legacy software into line with IEC 62304? - part 1

Most of medical devices manufacturers have legacy software that was not designed according to IEC 62304. The devices that embed legacy software were once verified and validated. These devices and their software work well and no major adverse event were raised by software issues.
But one day, the manufacturer decides that it's time to bring that legacy software into line with IEC 62304, to align the technical file of that software (or the contribution of software to technical file content) with up-to-date standard or regulatory requirements.

Continue reading...

Friday 15 February 2013

Wearable sensors: gadgets or useful medical devices?

Innovations in the field of medical devices are highly influenced by technologies like nano-sensors, bio-MEMS, and mobile platforms.
In this kind of devices, wearable sensors are emerging as the next must-have. Wearable sensors are tiny gadgets that you have permanently with you, hidden in your clothes or in a piece of jewelry. They monitor vital (or non-vital) signs like arterial pulse and transmit data to local computers or remote platforms. Data are analyzed on the receiver to control anything you want: high blood pressure...
Early adopters of such devices will surely be geeks or techno-victims, but we can bet in a few years everybody will have at least one.

A good example is the Shine by Misfits Wearables. It's a concentrate of technology that monitors body parameters and communicates with your smartphone. And it's a deliberately nice object!
For me it's also a concentrate of all buzzwords heard in innovative medical devices!

We don't know yet wether such objects will become truly useful medical devices or will remain gadgets. Wether they will change or not our habits, like smartphones did. That's the role of the market (doctors and the public) to say so.

Friday 8 February 2013

AAMI TIR45 on the use of agile methods becomes new FDA recognized standard

The AAMI TIR45:2012, Guidance on the use of AGILE practices in the development of medical device software enters in the list of recognized standards by the FDA. See here on Federal Register website.

Continue reading...

Friday 1 February 2013

FDA Draft Guidance on medical devices for home use

Too busy to write a long post this week.

I've not talked about a new FDA draft guidance yet:
The Draft Guidance for Industry and FDA Staff - Design Considerations for Devices Intended for Home Use.

Though not specific to software, this guidance has consequences on software design of medical devices for home use. The design team has to watch for problems linked to the users, their diseases and their environment where things can get messy.

Most of the content of that guidance is not intended to be applied specifically to software. But it contains a few elements that are applicable to software, mainly alarms, human factors, and use of device in emergency. That is another way of saying that ergonomics and human factors engineering are important input data for software development.

Monday 21 January 2013

Class A, B and C. Is it possible to reduce the documentation of detailed design of software medical devices?

In the last two posts, we've seen what a software unit is, and when to do software detailed design, according to IEC 62304 and FDA Guidances.

Continue reading...

Friday 18 January 2013

Class A, B and C. When to do detailed design of software medical devices?

In my last post, I explained what criteria should be taken to define the level of details of software units in a software design. This activity is not mandatory for all levels of risk of software in medical devices, though, according to IEC 62304.

Continue reading...

- page 1 of 5